Electric Jacket Heater Suitable For A 2 Stroke Main Engine

It is a flow‑through electric immersion heater, installed on the jacket cooling fresh water loop (parallel / branch circuit with circulating pump).

Shore‑supply / shipboard 3‑phase power feeds tubular heating elements inside pressure shell.

Circulated jacket fresh water flows across heated elements, absorbs heat.

Thermostat / PT100 sensor maintains standby temperature 50‑60 °C; pre‑start target ≥ 50 °C, max limit 80 °C Everllence.

Over‑temperature cut‑off & pressure relief fitted as safety interlock; output signal to engine alarm system.

Must run with forced water circulation; static immersion without flow will burn out heating elements.

System Installation Notes

Install together with a small circulation pump, cannot rely on main jacket water pump during stand‑still.

Mount on the deaeration tank circuit or JCW bypass loop; never install directly on engine main pipe.

Interlock logic: heater power cuts off if circulation pump trips or flow loss occurs.

Keep temperature at 50‑60 °C during stand‑by; do not continuously exceed 65 °C in idle conditionEverllence.

Back‑up option: Many vessels keep steam pre‑heater as primary, electric heater as reserve.

electric jacket heater suitable for a 2 Stroke Main engine

Common Failure Points

Scale build‑up on Incoloy elements → poor heat transfer, high surface temperature, element burnout.

Circulation pump failure without flow interlock → heater damage.

PT100 sensor drift → over‑heating risk.

Flange gasket leakage under thermal cycling.

 

Selection Required Data (for quotation / custom 1:1 replacement)

Main engine model 

Total jacket cooling water volume

Required heating kW

Ship voltage: 440 V 3‑phase or other

Flange dimension standard (DIN / JIS)

Class society requirement (DNV / ABS etc.)